Page 22 - 878272_LancerOrthodontics_Catalog_FOR WEB LowerRes
P. 22

TM

                                              Straight Forward Philosophy is a new
                                              complete orthodontic system.
                                              It is the result of 20 years of clinical experience
                                              achieved using Straight-Wire appliances.

New Brackets Praxis™ 2.0                      New Prescription

• New Design                                  • New Torque value on the Upper Lateral to counteract the tendency of slight proclination
• New Base                                      observed at the end of the orthodontic therapy.
• Improved
                                              • Increased lower arch incisor torque compared to the central incisors to reduce the tendency
  Performance                                   of the lateral to tilt in excess buccally.
• New in-out value
• New Prescription                            • New versatility with the possibility to use lower lateral brackets on the lower central anteriors.
                                              • Upper and lower cuspid brackets with 0’ torque. A more uprighted canine produces a more
New Molar Tube Praxis™ BT
                                                appealing aesthetic result, and improves the efficiency of canine lateral disclusion.
• New Design                                  • Upper first and second molar offset is increased to 14° to compensate the typical mesial
• New Base
• Miniature Tube                                rotation due to the archwire/slot play and the anchorage forces produces an appealing aesthetic
• Improved                                      result and improves the efficiency of canine lateral disclusion.
                                              • Lower second molar negative (-20°) torque is increased to alleviate the eccessive flattening
  Performance                                   of the Wilson curve in the second molar area.
• Versatility
                                              UPPER  12 345        6  7
                                       large
                                     medium    Roth  Tq° Tip° Tq° Tip° Tq° Tip° Tq° Tip° Tq° Tip° Tq° Tip° Rot° Tq° Tip° Rot°
                                              MBT*
                                       small    SFP  12 5 8 9 -2 13 -7 0 -7 0 -10 0 14 -10 0 14

20                                                   17 4 10 8 -7 8 -7 0 -7 0 -14 0 10 -14 0 10

                                                     17 4 8 8 0 8 -7 0 -7 0 -14 0 14 -14 0 14

                                              LOWER  12 345        6  7

                                                     Tq° Tip° Tq° Tip° Tq° Tip° Tq° Tip° Tq° Tip° Tq° Tip° Rot° Tq° Tip° Rot°

                                              Roth   -1 2 -1 2 -11 7 -17 -1 -22 -1 -25 0 4 -30 0 4

                                              MBT* -6 0 -6 0 -6 3 -12 2 -17 2 -20 0 0 -10 0 0

                                              SFP -6 0 -10 0 0 3 -12 2 -17 2 -20 0 0 -20 0 0

                                                                   *MBT is a trademark of 3M Unitek

                                              New Arch System

                                              Data from literature and research conducted on more than 40 non-treated patients with normal
                                              occlusion has shown that the patient arch-form variability is not usually due to the shape but to the
                                              initial intercuspid and intermolar diameters.
                                              The new arches ID-Form have been designed for the Technique Straight Forward Philosophy with
                                              the purpose to minimize the adaptation to the shape of the original arch form of the patient and
                                              to comply with the different widths of arches
                                              The ID-Form arches are available in all alloys (Thermal NiTi, Stainless Steel and Beta-Titanium) and
                                              dimensions designed in 1 original form and 3 “sizes” (small, medium and large). The 3 “sizes” are
                                              perfectly coordinated with each other, so that once the most appropriate size is chosen for the
                                              lower arch, you will have just to use the wider one for the upper.The ID- Form arch system improves
                                              the clinical efficiency and reduces the inventory costs.
                                              The new NiTi thermal-activated archwires have been designed to have consistent forces during
                                              the treatment and to be resistant to any permanent deformation expressing efficiency during the
                                              alignment phase.